GENERAL INFORMATION

NTEGRA Prima is a multifunctional device for performing the most typical tasks in the field of Scanning Probe Microscopy. The device is capable of performing more than 40 measuring methods, what allows analyzing physical and chemical properties of the surface with high precision and resolution. It is possible to carry out experiments in air, as well as in liquids and in controlled environment.

The new generation electronics provides operations in high-frequency (up to 5MHz) modes. This feature appears to be principal for the work with high-frequency AFM modes and using high-frequency cantilevers.*
There are several scanning types implemented in NTEGRA Prima: scanning by the sample, scanning by the probe and dual-scanning. On account of that, the system is ideal for investigating small samples with ultra-high resolution (atomic-molecular level) as well as for big samples and scanning range up to 100x100x10 µm.

The unique DualScan TM mode allows investigating even bigger fields on the surface (200×200 µm for X, Y and 22 µm for Z) that can be useful, for example, for living cells and MEMS components.

Built-in three axes closed loop control sensors trace the real displacement of the scanner and compensate unavoidable imperfections of piezoceramics as non-linearity, creep and hysteresis. The sensors, which are used by NT-MDT, have the lowest noise level, thus allowing working with closed loop control on the very small fields (down to 10×10 nm). This is especially valuable for carrying out nanomanipulation and lithography modes. NTEGRA Prima has a built-in optical system with 1 µm resolution, which allows imaging the scanning process in real-time.

Due to the open architecture, the functionality of NTEGRA Prima can be extended essentially: specialized magnetic measurements with external magnetic field, high-temperature experiments, Near-field optical microscopy, Raman spectroscopy, etc.

* E.g. the unique method of Atomic-Force Acoustic Microscopy (AFAM) allows investigating soft and hard samples with carrying out quantitative measurements of Young modulus in every scanning point. AFAM allows obtaining much better contrast as compared to Phase Imaging Mode for the soft objects, and makes possible the obtainment of contrast on the hard samples, what is a very hard task when one uses other methods.


APPLICATIONS

  • Biology and Biotechnology
    Proteins, DNA, viruses, bacteriums, tissues
  • Materials Science
    Surface morphology, surface morphology, local piezoelectric properties, local adhesion properties, local tribological properties
  • Magnetic materials
    Magnetic domain structure visualization, observation of magnetization reversal processes that depend on external magnetic field, observation of magnetization reversal processes under different temperatures
  • Semiconductors, electric measurements
    Wafers and other structures morphology, local surface potential and capacitance measurements, electric domain structure imaging, determination of heterojunction bounds and semiconductor regions with different doping levels, failure analysis (localization of conductor line failure and leakage in dielectric layers)
  • Polymers and Thin Organic Films
    Spherulites and dendrites, polymer monocrystals, polymer nanoparticles, LB-films, thin organic films
  • Data storage devices and medias
    CD, DVD disks, storages for terabit memories with thermomechanical, electric and other types of recording
  • Nanomaterials
    Nanopowders, nanocomposites, nanoporous materials
  • Nanostructures
    Fullerenes, nanotubes, nanofilaments, nanocapsules
  • Nanoelectronics
    Quantum dots, nanowires, quantum structures
  • Nanomachining
    AFM lithography: force (ac and dc), current (Local anodic oxidation), STM lithography
  • Nanomanipulations
    Contact force

SPECIFICATIONS

Measuring modes and techniques

In air&liquid In air only
– AFM (contact + semi-contact + non-contact)
– Lateral force microscopy
– Phase Imaging
– Force Modulation
– Adhesion Force Imaging
– Lithography: AFM (Force)
– STM
– Magnetic Force Microscopy
– Electrostatic Force Microscopy
– Scanning Capacitance Microscopy
– Kelvin Probe Microscopy
– Spreading Resistance Imaging
– Lithography: AFM (Current), STM
– AFAM (optional)

TECHNICAL DATA

 

Scan type Scanning by sample Scanning by probe*
Sample size Up to 40 mm in diameter,
to 15 mm in height
Up to 100 mm in diameter,
up to 15 mm in height
Sample weight Up to 100 g Up to 300 g
XY sample positiniong 5×5 mm 5×5 mm
Positioning resolution readable resolution – 5 um
sensitivity – 2 um
readable resolution – 5 um
sensitivity – 2 um
Scan range 100x100x10 um
3x3x2,6 um
Less than 1x1x1 um
100x100x10 um
50x50x5 um
Scan range Up to 200x200x20 um**(DualScanTM mode) Up to 200x200x20 um**(DualScanTM mode)
Non linearity, XY
(with closed loop sensors)
≤0.1% ≤0.15%
Noise level, Z
(RMS in bandwidth 1000 Hz)
With sensors 0.04 nm (typically),
≤0.06 nm
0.06 nm (typically),
≤0.07 nm
Noise level, Z
(RMS in bandwidth 1000 Hz)
Without sensors 0.03 nm 0.05 nm
Noise level, XY*** >(RMS in bandwidth 200 Hz) With sensors 0.2 nm (typically),
≤0.3 nm (XY 100 um)
0.1 nm (typically),
≤0.2 nm (XY 50 um)
Noise level, XY*** >(RMS in bandwidth 200 Hz) Without sensors 0.02 nm (XY 100 um),
0.001 nm (XY 3 um)
0.01 nm (XY 50 um)
Linear dimension estimation error
(with sensors)
± 0.5% ± 1.2%
Optical viewing system Optical resolution 1 um
(0.4 um optional, NA 0.7)****
3 um
Optical viewing system Field of view 4.5-0.4 mm 2.0-0.4 mm
Optical viewing system Continuous zoom available available
Vibration isolation Active 0.7-1000 Hz 0.7-1000 Hz
Vibration isolation Passive above 1 kHz above 1 kHz

 

* Scanning head can be configured to serve as a stand-alone device for specimens of unlimited sizes.
** Optionally can be expanded to 200x200x20 мm.
*** Built-in capacitive sensors have extremely low noise and any area down to 50×50 nm can be scanned with closed-loop control.
**** High Resolution Viewing system (HRV head) is optional and provides additional functionality making it possible to generate and detect tip-localized aperture less near-field effects.